Dynamics
Integration test report form $Revision: 1.5 $ State approved
Date 05-Dec-1998 Author Kimmo Mustonen
Review date 06-Dec-1998 Reviewed by Björn Andersson
Approval date 08-Dec-1998 Approved by Jouni Malinen
$Id: test_form_ha.html,v 1.5 1998/12/09 20:09:29 kmustone Exp $


The following integration test report of the Home Agent consists of test cases that are created based on the defined functionality in the functional definition and the technical definition.


Test result codes:
S = Successful
I = Improvements required
F = Failed
N = Not implemented (yet)

Date {date}
Tester {tester}
Modules {modules and versions}
ID
Test case
Result
Comments
HA01
The Home Agent starts successfully and gets the configuration information that it needs
HA02
On receipt of an Agent Solicitation Message, the Home Agent replies to the sender with an Agent Advertisement Message
HA03
On receipt of a Registration Request the Home Agent verifies the shared secret for the corresponding Mobile Node
HA04
On receipt of an invalid Registration Request, the Home Agent will reply with a code indication registration failure
HA05
On receipt of a valid Registration Request, the Home Agent will determine the lifetime and generate a Session Key and create a Mobility Binding and reply with a Registration Reply indicating that the registration was successful
HA06
Is the Mobile Node registers outside the home network, the proxy ARP functionality for the Mobile Node will be activated
HA07
If the lifetime of the Registration Request is zero, the Mobile Node is deregistered and the tunnel and proxy ARP functionality for that Mobile Node is disabled
HA08
If the lifetime timer for a mobility binding expires, tha Home Agent will purge the associated tunnel
HA09
The Home Agent logs the events that are defined to be logged in the functional definition
General comments {Comments}