Dynamics | ||
Integration test report form | $Revision: 1.5 $ | State approved |
Date 05-Dec-1998 | Author Kimmo Mustonen | |
Review date 09-Dec-1998 | Reviewed by Jouni Malinen | |
Approval date 09-Dec-1998 | Approved by Jouni Malinen |
$Id: test_form_mn.html,v 1.5 1998/12/09 20:09:29 kmustone Exp $
The following integration test report of the Mobile Node consists of
test cases that are created based on the defined functionality in the
functional definition
and the
technical definition.
Test result codes:
S = Successful
I = Improvements required
F = Failed
N = Not implemented (yet)
Date {date} | |||
Tester {tester} | |||
Modules {modules and versions} | |||
On receipt of a Registration Reply, the Mobile Node configures the tunnel and the timer is started | |||
If the Mobile Node changes its point of attachment the Mobile Node will register to the new Foreign Agent | |||
When the mobile notices that the Mobility Agent has been rebooted, the Mobile Node will reregister | |||
If the Mobile Node is returned to its home network, it will deregister itself | |||
An external signal saying that the point of attachment has changed causes the Mobile Node to send a Mobility Agent Solicitation message | |||
Before the lifetime timer expires, the Mobile Node starts to reregister with the Home Agent | |||
When the lifetime timer expires, the Mobile Node purges the associated tunnel | |||
The Mobile Node should reread the configuration file when it receives signal SIGHUP | |||
The Mobile Node should exit cleanly when it receives signal SIGTERM or SIGINT | |||
The Mobile Node logs the events that are defined to be logged in the functional definition | |||
General comments {Comments} |